{"id":9890,"date":"2021-03-02T11:13:54","date_gmt":"2021-03-02T10:13:54","guid":{"rendered":"http:\/\/guil.es\/producto\/tmd-570-rigging-tower-for-line-array-systems\/"},"modified":"2024-06-14T12:18:51","modified_gmt":"2024-06-14T10:18:51","slug":"rigging-tower-for-line-array-systems-ref-tmd-570","status":"publish","type":"product","link":"https:\/\/guil.es\/en\/products\/rigging-tower-for-line-array-systems-ref-tmd-570\/","title":{"rendered":"Compact design Line Array Tower
(Stowed volume: 3.68 m3)"},"content":{"rendered":"
[vc_row el_id=”tabs_componenetes”][vc_column][vc_column_text el_id=”edit-text” el_class=”edit-text”]<\/p>\n
Maximum height:\u00a0 8 m (26 ft 3 in) \u00a0\/ <\/strong>\u00a0Maximum load capacity:\u00a0 800 kg (1760 lb)<\/strong><\/p>\n [\/vc_column_text][\/vc_column][\/vc_row][vc_row preset=”preset_2″ content_preset=”_preset_2″ el_class=”boton_tab”][vc_column width=”8\/12″][\/vc_column][vc_column width=”1\/12″][\/vc_column][vc_column width=”1\/12″ el_class=”insert_botton” offset=”vc_hidden-md vc_hidden-sm vc_hidden-xs”] When GUIL launched their first compact line array tower, the TMD-545 (for 500kg up to 6.40m high) in 2003, it was a PIONEER in the industry, its wide popularity based on its ground-breaking design; cutting down on storage space and set-up times. The TMD-570 follows the innovative trail blazed by the TMD-545, and our extensive market research of the requirements of the events industry, to meet the increasingly frequent demands of professionals for similarly compact and original towers capable of lifting bigger sound systems.<\/p>\n [\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=”1\/2″][vc_column_text css=”.vc_custom_1718359670292{padding-top: 20px !important;padding-right: 15px !important;padding-left: 15px !important;}”]<\/p>\n QUICK AND EASY SET-UP:<\/u><\/strong>\u00a0 Familiar with the problems faced by technicians to install sound systems of these characteristics for outdoor events, GUIL have designed the TMD-570, which allows a single professional to raise the structure by means of an electric motor.<\/p>\n Its design allows the structure\u2019s mast to be raised to the vertical position with no need to rely on four or five people.\u00a0 With the TMD-570 tower, a professional needs only two minutes help from a colleague to start to raise the mast before completing the lifting process with the motor.<\/p>\n PRACTICAL & COMPACT FOR STORAGE AND TRANSPORT:<\/u>\u00a0 <\/strong>With its inventive construction and high performance, its quick set-up and reduced stowed dimensions in just one piece of 3.68 m3<\/sup><\/strong>, and its ease of transport and handling, the TMD-570 has the right to be regarded as one of the most practical structures on the market.\u00a0 Just one technician can move the TMD-570 on its wheels, using the handlebar to steer it, from the lorry to the set-up location.<\/p>\n <\/p>\n [\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/2″][vc_single_image image=”92198″ img_size=”full” css=”.vc_custom_1677657940327{padding-top: 15px !important;padding-right: 15px !important;padding-left: 15px !important;}”][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner][vc_column_text css=”.vc_custom_1718359694837{padding-top: 20px !important;padding-right: 15px !important;padding-left: 15px !important;}”]<\/p>\n The TMD-570 tower is the perfect solution for events where a Line Array tower with a large lifting height and maximum load capacity is required and where storage space and transport are also an important factor.<\/p>\n The TMD-570 is supplied with a chain bag (Ref. BLC-01) to keep the chain of the electric motor.<\/p>\n [\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner][vc_column_text css=”.vc_custom_1716821097695{padding-top: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;}”]<\/p>\n DESIGNED FOR OUTDOOR EVENTS:<\/u><\/strong> The TMD-570 was specially conceived for outdoor use (though, naturally, it may also be used indoors), and is supplied with an interactive application, the \u201cTMD-570 APC\u201d, which helps the user to calculate the maximum permissible wind speed, according to the EU norm (EN 13814) for this purpose, taking into account the weight and height for the line array to be used on each occasion.<\/p>\n MAXIMUM SAFETY AND RELIABILITY:<\/u> <\/strong>For GUIL, the first priority at all times is the safety of everybody using or near our products.\u00a0 For this reason, we work only with the most up-to-date technological solutions and the highest-quality materials to fulfil the projects of our engineering department, and the TMD-570 is a clear example of this rule.\u00a0 The certified strength and stability of this tower, conceived and built to hold 800 kg of line array at a height of 8 metres, are achieved by its intelligent design and reinforced construction, and guarantee the protection of both the line array itself and, of course, of the public attending the event.<\/p>\n [\/vc_column_text][\/vc_column_inner][\/vc_row_inner]<\/div><\/div> The TMD-570 rigging tower has been designed to be as quick and easy as possible to assemble, while at the same time making safety a priority.\u00a0 The front legs of the tower are attached to the base, and swing out to be anchored in their splayed position at the front of the tower.\u00a0 The side stabilisers are inserted into their housings and held in place with magnetic locking pins (Ref. RC-100\/L).<\/p>\n The truss sections of the TMD-570 are designed to be assembled horizontally, before being attached to the hinges on the base of the tower and raised into a vertical position with the electric motor (not supplied: we recommend using a 1000 kg capacity motor).<\/p>\n The tower is then levelled using the screw jacks on the legs and side stabilisers and the spirit level on the base.\u00a0 This system guarantees quick and easy assembly and take-down of the tower, which can be carried out by only two people.<\/p>\n The trapezoidal section truss stages were created in GUIL\u2019s technical department with the aim of designing a high-strength lifting mast specifically for outdoor use which, at the same time, would be quick to assemble and would occupy as little space as possible with an eye to storage and to transport.<\/p>\n In addition to lifting the sound apparatus and raising the aluminium structure to its vertical position, the chain of the motor also acts as an auxiliary strut, giving the tower great solidity and resistance.\u00a0 NOTE:\u00a0 We recommend using a motor with 1000 kg load capacity.<\/p>\n <\/p>\n [\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/4″][vc_single_image image=”92230″ img_size=”full” alignment=”center” css=”.vc_custom_1677679837635{padding-bottom: 20px !important;}”][\/vc_column_inner][\/vc_row_inner]<\/div><\/div> TRUSS SECTIONS:<\/u>\u00a0 \u00a0<\/strong>The mast section consists of five 1500mm sections of truss in a trapezoidal design (400mm wide at the back, 650mm at the front), which allows the sections to be stacked together vertically on the base for storage and transport.\u00a0 \u00a0Three adjustable strengthening braces are supplied to reinforce the sections, and the truss sections are connected with zero play for maximum security. The truss sections of the tower have been specially designed by GUIL\u2019s engineers to provide maximum strength and reliability, while also stacking together for storage and transport to occupy a mere 3.68 m3<\/sup><\/strong> when stowed on its wheeled base.<\/p>\n [\/vc_column_text][vc_column_text css=”.vc_custom_1718348951234{padding-top: 15px !important;padding-right: 15px !important;padding-left: 15px !important;}”]<\/p>\n TRUSS SPACERS:<\/u><\/strong> Each truss section is supplied with an adjustable truss spacer to reinforce the sections and prevent deformation (5 truss spacers in total).<\/p>\n [\/vc_column_text][vc_column_text css=”.vc_custom_1718348973134{padding-top: 15px !important;padding-right: 15px !important;padding-left: 15px !important;}”]<\/p>\n STRENGTHENING BRACES:<\/u><\/strong> The truss tower itself is equipped with two strengthening braces or brace bars to withstand large loads and maintain the stability of the structure. Each brace is secured with a brace fastener with double clamps to the trusses and to the front legs with specially-made brackets, to form a strong and stable unit.<\/p>\n [\/vc_column_text][vc_column_text]<\/p>\n \u00a0 \u00a0 <\/p>\n [\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″][vc_single_image image=”208673″ img_size=”470×415″ alignment=”right” css=”.vc_custom_1718359755333{padding-top: 15px !important;padding-right: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;}”][\/vc_column_inner][\/vc_row_inner]<\/div><\/div> The head block consists of two 1290mm-long aluminium beams and, in combination with the 5\u00ba inclination of the truss structure, assures the correct degree of inclination for the line array.\u00a0 It can be detached from the tower to be stored in the base for transport, or also to be placed on the ground to assemble the tower and to install the chain of the motor.\u00a0 The headblock is fitted with a large silentblock to protect it when setting up and taking down the tower.<\/p>\n [\/vc_column_text][vc_single_image image=”208051″ img_size=”full” alignment=”center”][\/vc_column_inner][vc_column_inner width=”1\/4″][vc_single_image image=”92218″ img_size=”full” alignment=”right”][\/vc_column_inner][\/vc_row_inner]<\/div><\/div> UNIQUE DESIGN<\/u>: <\/strong>The base of the TMD-570 is the result of revolutionary design and pioneering execution, with the dual purpose of forming the foundation of the line array tower when it is in use, and accommodating all the components of the tower in one block for transport and storage, thus avoiding loss of components. \u00a0The base (with dimensions of just 940×1865<\/strong> mm<\/strong>) is fitted with custom-made nylon protectors to prevent damage from scratches or blows and to keep your TMD-570 in perfect condition, and also has a spirit level to help with the process of levelling the tower during assembly.<\/p>\n MOTOR MOUNTING:<\/u><\/strong> For the electric motor, GUIL have created a special mounting which fits under the base for transport and storage, but is pulled out to form an anchor point for the chain, which creates a brace to provide maximum strength and stability to the rigging tower, and greater support for the load.<\/p>\n LEGS AND STABILISERS<\/u>:\u00a0 <\/strong>The folding legs are installed on the base, and the side stabilisers are housed in the side members of the base, they are fitted with leveller screw jacks that have reinforced nylon injection moulded spin handles (ergonomic design) with double thread and speed which facilitates the levelling task. Their non-slip foot plates ensure a perfect adjustment of the tower to the floor surface.<\/p>\n The legs and side stabilisers provide further support for the lifter and guarantee the 360\u00ba support that is essential for a device that operates close to large numbers of people.<\/p>\n [\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″][vc_single_image image=”208679″ img_size=”full”][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner][vc_column_text css=”.vc_custom_1716821416110{padding-top: 10px !important;padding-right: 15px !important;padding-left: 15px !important;}”]<\/p>\n TRANSPORT:<\/u><\/strong>\u00a0 The base is fitted with four 150mm-diameter wheels with brakes for easy transport, making the TMD-570 highly manoeuvrable, and the motor support includes a handlebar to steer it.\u00a0 A single technician can move the base loaded with all the components of the TMD-570 wherever necessary.\u00a0 Just one person moving a whole line array tower to lift 800kg to 8 metres height:\u00a0 who can resist that?<\/strong><\/p>\n [\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=”5\/12″ css=”.vc_custom_1677768594433{padding-right: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;}”][vc_single_image image=”208675″ img_size=”full” alignment=”center” css=”.vc_custom_1718360115065{padding-top: 30px !important;padding-right: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;}”][\/vc_column_inner][vc_column_inner width=”1\/4″ css=”.vc_custom_1677768636465{padding-right: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;}”][vc_single_image image=”208663″ img_size=”full” alignment=”center” css=”.vc_custom_1718360131432{padding-top: 30px !important;}”][\/vc_column_inner][vc_column_inner width=”1\/4″ css=”.vc_custom_1677768630385{padding-right: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;}”][vc_single_image image=”208677″ img_size=”full” alignment=”center” css=”.vc_custom_1718360144252{padding-top: 40px !important;}”][\/vc_column_inner][vc_column_inner width=”1\/12″][\/vc_column_inner][\/vc_row_inner]<\/div><\/div> [\/vc_column_text][vc_column_text css=”.vc_custom_1677672361610{padding-top: 15px !important;}”]<\/p>\n The TMD-570 Rigging Tower complies with the requirements of safety according to the following Standards and Regulations:<\/strong><\/p>\n [\/vc_column_text][vc_column_text css=”.vc_custom_1714475450062{padding-top: 20px !important;padding-right: 60px !important;}”]<\/p>\n \u25aa Directive 2006\/42\/CE <\/strong>on machinery that establish \u201cEssential health and safety requirements relating to the design and construction of machinery\u201d. [\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″ css=”.vc_custom_1677669450765{padding-right: 15px !important;padding-left: 15px !important;}”][vc_single_image image=”92222″ img_size=”large” alignment=”center” css=”.vc_custom_1677669912215{padding-bottom: 15px !important;}”][\/vc_column_inner][\/vc_row_inner][vc_row_inner css=”.vc_custom_1677571882492{padding-top: 5px !important;}”][vc_column_inner width=”1\/6″ css=”.vc_custom_1677669440078{padding-right: 15px !important;padding-left: 15px !important;}”][\/vc_column_inner][vc_column_inner width=”1\/2″ css=”.vc_custom_1677669667034{padding-right: 15px !important;padding-left: 15px !important;}” offset=”vc_hidden-lg vc_hidden-md”][vc_column_text css=”.vc_custom_1677672608786{background-color: #000000 !important;}”]<\/p>\n <\/p>\n [\/vc_column_text][vc_column_text css=”.vc_custom_1677672592447{padding-top: 15px !important;}”]<\/p>\n The TMD-570 Rigging Tower complies with the requirements of safety according to the following Standards and Regulations:<\/strong><\/p>\n <\/p>\n [\/vc_column_text][vc_column_text css=”.vc_custom_1716821499313{padding-top: 20px !important;padding-right: 60px !important;}”]<\/p>\n \u25aa Directive 2006\/42\/CE <\/strong>on machinery that establish \u201cEssential health and safety requirements relating to the design and construction of machinery\u201d. [\/vc_column_text][vc_column_text css=”.vc_custom_1677669932252{padding-top: 15px !important;padding-bottom: 15px !important;}”]<\/p>\n <\/p>\n [\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/3″ css=”.vc_custom_1677669450765{padding-right: 15px !important;padding-left: 15px !important;}”][\/vc_column_inner][\/vc_row_inner]<\/div><\/div> [\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/4″ css=”.vc_custom_1612887486975{padding-left: 15px !important;}”][vc_column_text]<\/p>\n [\/vc_column_text][\/vc_column_inner][vc_column_inner width=”1\/4″][\/vc_column_inner][vc_column_inner width=”1\/4″][\/vc_column_inner][\/vc_row_inner][vc_empty_space height=”200″]<\/div><\/div> RELATED PRODUCTS<\/p>\n<\/div>[\/vc_column_inner][\/vc_row_inner][vc_row_inner preset=”preset_3″ content_preset=”_preset_3″ css=”.vc_custom_1604673108690{margin-top: 5px !important;margin-bottom: 60px !important;padding-top: 0px !important;}” el_class=”force-center”][vc_column_inner width=”1\/5″ css=”.vc_custom_1600097178272{padding-bottom: 60px !important;}”][\/vc_column_inner][vc_column_inner width=”3\/5″ css=”.vc_custom_1604665675829{margin-top: 0px !important;padding-top: 0px !important;}”]TMD-570 \u2013 THE ULTIMATE 8-METRE RIGGING TOWER<\/strong><\/span><\/h5>\n
\n\u25aa EN 13814: <\/strong>Fairground and amusement park machinery and structures.
\n<\/strong>\u25aa EN 17206<\/strong> (Replaces DIN 56950-1<\/strong>) Entertainment technology – Machinery for stages and other production areas – Safety requirements and inspections.
\n<\/strong>\u25aa <\/strong>DGUV Regulations 17 & 18<\/strong>: Accident prevention regulation. Event and production facilities for scenic presentation.
\n\u25aa DGUV Rule 115-002: <\/strong>Staging and Production Facilities for the Entertainment Industry.<\/p>\nTMD-570 \u2013 THE ULTIMATE 8-METRE RIGGING TOWER<\/strong><\/span><\/h5>\n
\n\u25aa EN 13814: <\/strong>Fairground and amusement park machinery and structures.
\n<\/strong>\u25aa EN 17206<\/strong> (Replaces DIN 56950-1<\/strong>) Entertainment technology – Machinery for stages and other production areas – Safety requirements and inspections.
\n<\/strong>\u25aa <\/strong>DGUV Regulations 17 & 18<\/strong>: Accident prevention regulation. Event and production facilities for scenic presentation.
\n\u25aa DGUV Rule 115-002: <\/strong>Staging and Production Facilities for the Entertainment Industry.<\/p>\n\r\n TMD-570 Technical Specifications<\/a>\r\n <\/h3>\r\n
\r\n GUIL - Static Analysis & Certificate _TMD-570 Rigging Tower<\/a>\r\n <\/h3>\r\n